Welding Cable- YH / YHF
- Commodity name: Welding Cable- YH / YHF
- Nominal voltage: 450/750 V
- Material: Rubber insulated cables
- Ambient temperature: Fixed: -40°C to +85°C;Flexed: -20°C to +85°C
Product Detail
1.Introduction
Welding Cable is used for connections between the electrode holder and clamp, to the arc welder, bus, welding box or transformer. Recommended for use in industrial applications such as shipyards, mines and construction sites where resistance to extreme physical abuse and high flexibility are required.
2.Standard
IEC 60245-6: Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 6: Arc welding electrode cables
3.Instruction of Application
Temperature Rating
Fixed: -40°C to +85°C
Flexed: -20°C to +85°C
Minimum Bending Radius
Flexed: 6 x overall diameter
4.Construction
1.Conductor
Class 5 flexible copper conductor
2.Separator
PET (Polyester Tape)
3.Sheath
Natural Rubber (YH) / Rubber Compound (YHF)
4.DC resistances of class 6 copper conductor in 20℃
Nominal Area mm2 | 16 | 25 | 35 | 50 | 70 | 95 | |
Max. Single Wire diameter mm | 0.21 | 0.21 | 0.21 | 0.21 | 0.21 | 0.21 | |
Resistances Ω/km | No tin-coat | 1.16 | 0.758 | 0.536 | 0.379 | 0.268 | 0.198 |
Tin- coat | 1.19 | 0.780 | 0.552 | 0.390 | 0.276 | 0.204 |
5.Specification Data
Specification | Average thickness of Insulation mm | Average Outer Diameter mm | Approximate weight kg/km | |
16 | 2.0 | 8.8 | 11.0 | 215 |
25 | 2.0 | 10.1 | 12.7 | 310 |
35 | 2.0 | 11.4 | 14.2 | 414 |
50 | 2.2 | 13.2 | 16.5 | 550 |
70 | 2.4 | 15.3 | 19.2 | 739 |
95 | 2.6 | 17.1 | 21.4 | 979 |
Keywords:
Welding Cable- YH / YHF
Factory Appearance
Qualification certification
Quick Quote
* Note: Please be sure to fill in the information accurately and keep the communication open. We will get in touch with you as soon as possible
Copyright © 2023 Shandong Zhongmai Cable Co., Ltd