Medium Voltage Cable Cu/XLPE/CTS/SWA/PVC
Large current carrying capacity
Good catenary property and wear-resistance
Anti-crush and corrosion-proof with simple structure
- Commodity name: Medium Voltage Cable Cu/XLPE/CTS/SWA/PVC
- Nominal voltage: 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV)
- Material: XLPE (Cross-Linked Polyethylene)
- Ambient temperature: -20 ℃ to 90 ℃
Product Detail
Datasheet:
Introduction
This cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 36kV or lower. They are suitable for installations indoors: mostly in power supply stations and outdoors: in cable ducts, underground, and on cable trays for industries, switch-boards and power stations.
Executive standard
IEC60502-2 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV)
Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
Instruction of application
Rated Voltage:
● 3.6/6 (7.2) kV
● 6.0/10(12) kV
● 8.7/15(17.5) kV
● 12/20(24) kV
● 18/30(36) kV
The ambient temperature for cable installation :≥0 ℃
This minimum working temperature of the cable is -20 ℃
This maximum working temperature of the conductor is 90 ℃;
During having a short (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250 ℃;
Bending radius allowance of the cable:
Type of cable | Minimum Bending Radius (mm) | |
During Installation | Adjacent to joints or terminals | |
Single Core Cables | 15D | 12D |
Three Core Cables | 12D | 10D |
Cable Construction Description
Conductor
Class 2 stranded circular or circular compacted
Semi-Conductive Layer for Conductor
Semi-conductive material
Insulation
XLPE (Cross-Linked Polyethylene)
Semi-Conductive Layer for Insulation
Semi-conductive material
Metallic screen
Copper wires / Copper Tape / Copper Wire & Tape
Inner Sheath
PVC (Polyvinyl Chloride)
Amoured
STA- Steel Tape Amoured
Non-magnetic amoured material used for single core cable.
Outer Sheath
PVC (Polyvinyl Chloride)
The conductor Semi-Conductive Layer, XLPE insulation and the insulation Semi-Conductive Layer are extruded simultaneously in one process using triple extrusion method (Continuous Vulcanization Line). Triple extrusion method not only assures clean interfaces between the insulation and stress control layers, but also assures a construction free of Partial Discharge with high operational reliability.
The Main Technical Parameter Of The Cable
1) Cable conductor DC resistance: See the table 1-1
2) Partial discharge test: See the table 1-2
3) AC voltage test: See the table 1-3
4) Rated Voltage,Core Numbers & Nominal Cross-section Area : See the table1-4
Table 1-1 Max. DC resistance of cable conductor at 20 0C
Rated cross area (mm2) | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | |
Cu (Ω/km) | Non tinned | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 |
Tinned | 1.16 | 0.734 | 0.529 | 0.391 | 0.270 | 0.195 | 0.154 | 0.126 | |
Al (Ω/km) | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | |
Rated cross area (mm2) | 185 | 240 | 300 | 400 | 500 | 630 | 800 | 1000 | |
Cu (Ω/km) | Non tinned | 0.0991 | 0.0754 | 0.0601 | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0176 |
Tinned | 0.100 | 0.0762 | 0.0607 | 0.0475 | 0.0369 | 0.0286 | 0.0224 | 0.0177 | |
Al ( Ω/km) | 0.164 | 0.125 | 0.100 | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 |
Table 1-2 Test Voltage & Max. Discharge capacity of cable
Rated Voltage (kV) | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/30 | 21/35 | 26/35 |
Test Voltage (kV) | 6.23 | 10.38 | 15.05 | 20.76 | 31.14 | 36.33 | 44.98 |
Discharge capacity (pC) | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Table 1-3 AC voltage test of cable
Rated Voltage (kV) | 3.6/6 3.6/10 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/30 | 21/35 | 26/35 |
Test Voltage (kV) | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test Time (min) | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
Table 1-4 Rated Voltage, Core Numbers & Nominal Cross-section Area
U0/Um Area mm2 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Core No. | 1 | 25-630 | 25-630 | 35-630 | 35-630 | 50-630 | 50-630 | 50-630 |
3 | 25-400 | 25-400 | 35-400 | 35-400 | 50-400 | 50-400 | 50-400 |
Keywords:
Medium Voltage Cable Cu/XLPE/CTS/SWA/PVC
Factory Appearance
Qualification certification
Quick Quote
* Note: Please be sure to fill in the information accurately and keep the communication open. We will get in touch with you as soon as possible
Copyright © 2023 Shandong Zhongmai Cable Co., Ltd