Zimbabwe DUPLEX SERVICE DROP ABC CABLE

High strength
Large current carrying capacity
Good catenary property and wear-resistance
Anti-crush and corrosion-proof with simple structure

Category:

ZimbabweAerial Bundle Cable

Product Description

Applicaton
RMJT Cable overhead service drop cable is intended to deliver power from the secondary power line or pole-mounted transformer to the service-entrance conductors at the user’s building or other structure.
Duplex is intended to deliver single-phase power.
Triplex is intended to deliver 3-wire single-phase power.
Quadruplex is intended to deliver 4-wire three-phase power.
Multiplex Overhead Service Drop are ideal for use as pole line secondary with service splices at the pole or in mid-span.

Specifications

Insulation Material: XLPE /PE/PVC
Conductor Material: Aluminum,Aluminum alloy
Cable Type: Duplex, Triplex, Qudruple
Neutral conductor: AAC or 6201 Alloy or ACSR
Standard: ASTM,  IEC, NFC
Certificate: ISO9001, ISO14001, CE

Features
Multiplex overhead service drop cables are resistant to weathering, abrasion, tearing, cutting and Chemicals.
Working rated voltage is 0.6/1KV with a maximum conductor-rated operating temperature of 90C for Cross-linked Polyethylene insulation, and temperature is 75C if insulation is Polyethylene.

Construction
One. two or three aluminum conductors insulated with extruded lead-free Cross-linked Polyethylene (XLPE) cabled with a bare conductor which serves as a supporting neutral. Neutral-Supported cable meets the requirements of ANS/ICEA Standard S-76-474.
The all-aluminum stranded conductors are Class A or Class B compressed 1350-H19 aluminum. Solid conductors are H16 temper.
The insulation is extruded black lead-free Cross-linked Polyethylene(XLPE). PE and PVC are optional.
The all-aluminum stranded conductor is Class AA or Class A 1350-H19 (AAC) or 6201-T81 alloy (AAAC).
The aluminum conductor steel reinforced (ACSR) is Class AA. The direction of lay of the outer layer is right-hand.
Phase identification is provided by means of white print legend markings or ribs on the phase conductor depending on the cable construction.
DUPLEX SERVICE DROP

Code word AWG or kcmil Bare Neutral Messenger Phase Conductor Weight (kg/km)
AAC Stranding      and Wires Dia. (mm) Rated Streng ht (Ibs) AAC Insul. Thick. (mm)
Stranding and Wires Dia.(mm)
Pekingese 1*6AWG+1*6AWG 7/1.56 563 1/4.11 1.14 92
Collie 1*6AWG+1*6AWG 7/1.56 563 7/1.56 1.14 94
Dachshund 1*4AWG+1*4AWG 7/1.96 881 1/5.19 1.14 139
Spaniel 1*4AWG+1*4AWG 7/1.96 881 7/1.96 1.14 141
Doberman 1*2AWG+1*2AWG 7/2.47 1350 7/2.47 1.14 216
Malemute 1*1/0 AWG+1*1/0 AWG 7/3.12 1990 19/1.89 1.52 347

 

Code word AWG or kcmil Bare Neutral Messenger Phase Conductor Weight (kg/km)
ACSR Stranding and Wires Dia. (mm) Rated Strength (Ibs) AAC Insul. Thick. (mm)
Stranding and Wires Dia.(mm)
Setter 1*6AWG+1*6AWG 1/1.68+6/1.68 1190 1/4.11 1.14 109
Shepherd 1*6AWG+1*6AWG 1/1.68+6/1.68 1190 7/1.56 1.14 113
Eskimo 1*4AWG+1*4AWG 1/2.12+6/2.12 1860 1/5.19 1.14 166
Terrier 1*4AWG+1*4AWG 1/2.12+6/2.12 1860 7/1.96 1.14 169
Chow 1*2AWG+1*2AWG 1/2.67+6/2.67 2850 7/2.47 1.14 259
Bull 1*1/0 AWG+1*1/0 AWG 1/3.37+6/3.37 4380 19/1.89 1.52 415

 

Code word AWG or kcmil Bare Neutral Messenger Phase Conductor Weight (kg/km)
AL-ALLOY Stranding and Wires and Dia. (mm) Rated Strength (Ibs) AAC Insul. Thick. (mm)
Stranding and Wires Dia.(mm)
Chihuahhua 1*6AWG+1*30.58 7/1.68 1110 1/4.11 1.14 98
Vizsla 1*6AWG+1*30.58 7/1.68 1110 7/1.56 1.14 100
Harrier 1*4AWG+1*48.69 7/2.12 1760 1/5.19 1.14 149
Whippet 1*4AWG+1*48.69 7/2.12 1760 7/1.96 1.14 151
Schnauzer 1*2AWG+1*77.47 7/2.67 2800 7/2.47 1.14 231
Heeler 1*1/0AWG+1*123.3 7/3.37 4460 19/1.89 1.52 372